> Product Features
Experience unmatched safety and efficiency with our transformer! It is flame retardant, fireproof, and environmentally friendly, perfectly suited for direct installation in load centers. Enjoy maintenance-free operations, effortless installation, and remarkably low operational costs. Our transformer boasts superb moisture-proof capabilities, functioning flawlessly under 100% humidity and requiring no pre-drying post-shutdown. Benefit from minimal local discharge, low noise levels, and exceptional heat dissipation, allowing operation at 150% of the rated load with forced air cooling. Equipped with an advanced temperature protection control system, our transformer guarantees reliable and safe performance. Proven by the operational excellence of over 10,000 units, our product meets and exceeds international advanced standards. l.
Transformer TypeTransformer |
Resin Cast Dry Type |
Model
|
SCB10-50/10 |
Number of Phase |
Three Phase |
Winding Type |
Two Winding |
Winding Material |
Aluminum/Copper |
Rated Capacity |
50kVA |
High Voltage |
10/11kV |
Low Voltage |
0.4kV |
Tapping Ran |
±2x2.5% |
Impedance Voltage |
4% |
Load Loss (120°C) |
1kW |
No-load Loss |
0.27kW |
No-load Current |
2% |
Frequency |
50/60Hz |
Connection Group |
Yyn0/Dyn11 |
Cooling Method |
ANAF |
Insulation Class |
F |
Thermal Class |
F1 |
Operation Altitude |
≤1000m≤ 1000 m |
|
|
>> Technical Performance Parameters
1. Number of phases: 3 phases; Frequency: 50Hz
2. Partial discharge: not more than 10pC
3. Insulation heat-resistant grade: F grade
4. Average temperature rise of winding: not more than 100K
5. Noise level: Sound level in accordance with GB/T22072-2008
Leverage our robust technical expertise and state-of-the-art equipment, sourced from both domestic and international suppliers. Our innovative approach, extensive manufacturing experience, and broad product range set us apart. We proudly hold ISO9001 international quality management system certification and CCC certification, and we have been recognized as a national high-tech enterprise among other prestigious accolades.
Packaging and Transportation
Quotation and Ordering Required Information:
Transformer Type:
Rated Capacity: kVA
Phase: ( ) Three Phase ( ) Single Phase
Frequency: ( ) 50Hz ( ) 60Hz
Rated Voltage (HV/LV): kV / kV
Tapping Range:
±
x%
Insulation Level: LIAC/ LIAC
Vector Group: ( ) Dyn11 ( ) Yyn0 ( ) Other
Short-circuit impedance: Uk=%
Service conditions: Altitude: m
Ambient temperature:ºC
Cooling Method: ( ) ONAN ( ) ONAF
Oil labeling:
Quantities ordered and time of delivery:
Other requirements:
(